|  | Rolling Stock Cables     RSE/STD/024 PART 6RSE/STD/024 Part 6 Rolling Stock Cable 300/500V Multipair RSE/STD/024 Part 6 Rolling Stock Type Ⅷ screened Cable, with jacket   
                
                  | Cross- sectional Area | 0.5mm2-1.0mm2 |  
                  | Voltage rating | 30/50V |  
                  | Conductor | Flexible Stranded Tinned Copper |  
                  | Number of pairs | 1,2,3 |  
                  | Conductor class | IEC 60228 Class 5 |  
                  | Screen | Copper Braid Screen |  
                  | Insulation | Cross linked EPR rubber type EI 107, Standard wale |  
                  | Jacket | Cross linked EVA rubber type EM 104 |  
                  | Fire standard | IEC 332-3C,IEC754;IEC1034-1/2 |  
 
                
                  | No. of Pairs | Cross Sectional Area (mm2) | Number and Nominal Diameter of Strands (mm) | Voltage Rating (V) | Nominal OverallDiameter
 (mm) | Nominal Weight (kg/km) |  
                  | 1 Pair | 0.5 | 16/0.2 | 30/50 | 8.45 | 99.0 |  
                  | 1 Pair | 0.75 | 24/0.2 | 30/50 | 9.2 | 110.0 |  
                  | 1 Pair | 1.0 | 32/0.2 | 30/50 | 9.5 | 139.0 |  
                  | 1 Pair | 1.0 | 32/0.2 | 30/50 | 11.7 | 186.0 |  
                  | 1 Pair | 1.0 | 32/0.2 | 30/50 | 15.6 | 306.0 |  
                  | 2 Pair | 1.0 | 32/0.2 | 30/50 | 15.7 | 443.0 |  
                  | 3 Pair | 1.0 | 32/0.2 | 30/50 | 21.7 | 662.0 |   300/500V Multipair RSE/STD/024 Part 6 Rolling StockType Ⅸ screened Cable, with jacket 
 
                
                  | Cross- sectional Area | 0.5mm2-1.0mm2 |  
                  | Voltage rating | 300/500V |  
                  | Conductor | Flexible Stranded Tinned Copper |  
                  | Number of pairs | 1,2,3,4 |  
                  | Conductor class | 19/37 AWG Stranding |  
                  | Insulation | Cross linked EPR rubber type EI 107, Reduced Wall |  
                  | Screen | Copper Braid Screen |  
                  | Jacket | Cross linked EVA rubber type EM 104 |  
                  | Fire standard | IEC 332-3C,IEC754;IEC1034-1/2 |  
 
                
                  | No. of Pairs | Cross Sectional Area (mm2) | Number and Nominal Diameter of Strands (mm) | Voltage Rating (V) | Nominal OverallDiameter
 (mm) | Nominal Weight  (kg/km) |  
                  | 1 Pair | 0.5 | 19/0.18 | 30/50 | 6.1 | 57.0 |  
                  | 2 Pair | 0.5 | 19/0.18 | 30/50 | 10.2 | 110.0 |  
                  | 1 Pair | 1.0 | 37/0.18 | 30/50 | 7.0 | 85.0 |  
                  | 2 Pair | 1.0 | 37/0.18 | 30/50 | 12.2 | 187.5 |  
                  | 3 Pair | 1.0 | 37/0.18 | 30/50 | 12.9 | 217.0 |  
                  | 4 Pair | 1.0 | 37/0.18 | 30/50 | 14.0 | 290.0 |   600/1000V Singlecore RSE/STD/024 Part 6 Rolling Stock TypeⅠCable, unsheathed   
                
                  | Cross-sectional Area | 0.5mm2-4mm2 |  
                  | Voltage rating | 600/1000V |  
                  | Conductor | Flexible Stranded Tinned Copper |  
                  | Number of cores | 1 |  
                  | Conductor class | 19/37 AWG Stranding |  
                  | Insulation | Cross linked EPR rubber type EI 107 Reduced wall |  
                  | Fire standard | IEC 332-3C,IEC754;IEC1034-1/2 |  
 
                
                  | No. of Cores | Cross Sectional Area (mm2) | Number and Nominal Diameter of Strands (mm) | Voltage Rating (V) | Nominal OverallDiameter
 (mm) | Nominal Weight  (kg/km) |  
                  | singlecore | 0.5 | 19/0.18 | 600/1000 | 1.5 | 5.9 |  
                  | singlecore | 0.75 | 37/0.16 | 600/1000 | 1.76 | 8.7 |  
                  | singlecore | 1.0 | 37/0.18 | 600/1000 | 1.9 | 10.7 |  
                  | singlecore | 1.5 | 37/0.23 | 600/1000 | 2.25 | 16.5 |  
                  | singlecore | 2.5 | 37/0.3 | 600/1000 | 2.84 | 28.0 |  
                  | singlecore | 4.0 | 37/0.37 | 600/1000 | 3.44 | 42.0 |   600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅱ Cable, unsheathed   
                
                  | Cross- sectional Area  | 0.75mm2-300mm2 |  
                  | Voltage rating  | 600/1000V |  
                  | Conductor | Flexible Stranded Tinned Copper |  
                  | Number of cores  | 1 |  
                  | Conductor class  | IEC 60228 Class 5 |  
                  | Insulation | Cross linked EPR rubber type EI 107, Standard Wall |  
                  | Fire standard | IEC 332-3C,IEC754;IEC1034-1/2 |  
 
                
                  | No. of Cores/Pairs | Cross Sectional Area (mm2) | Number and Nominal Diameter of Strands (mm) | Voltage Rating (V) | Nominal OverallDiameter
 (mm) | Nominal Weight  (kg/km) |  
                  | singlecore | 0.75 | 24/0.2 | 600/1000 | 2.99 | 14.9 |  
                  | singlecore | 1.0 | 32/0.2 | 600/1000 | 3.3 | 19.2 |  
                  | singlecore | 1.5 | 30/0.25 | 600/1000 | 3.69 | 26.3 |  
                  | singlecore | 2.5 | 50/0.25 | 600/1000 | 4.16 | 37.8 |  
                  | singlecore | 4.0 | 56/0.3 | 600/1000 | 4.95 | 56.6 |  
                  | singlecore | 6.0 | 84/0.3 | 600/1000 | 5.55 | 80.4 |  
                  | singlecore | 10.0 | 80/0.4 | 600/1000 | 7.0 | 135.0 |  
                  | singlecore | 16.0 | 128.4 | 600/1000 | 8.35 | 201.8 |  
                  | singlecore | 25.0 | 196/0.4 | 600/1000 | 10.2 | 3.9.3 |  
                  | singlecore | 35.0 | 2/6/0.4 | 600/1000 | 11.75 | 404.1 |  
                  | singlecore | 50.0 | 396/0.4 | 600/1000 | 13.7 | 562.0 |  
                  | singlecore | 70.0 | 360/0.5 | 600/1000 | 16.25 | 768.0 |  
                  | singlecore | 95.0 | 476/0.6 | 600/1000 | 18.05 | 1002.8 |  
                  | singlecore | 150.0 | 756/0.5 | 600/1000 | 22.95 | 1583.0 |  
                  | singlecore | 240.0 | 1221/0.5 | 600/1000 | 27.9 | 2516.0 |  
                  | singlecore | 300.0 | 1525/0.5 | 600/1000 | 31.35 | 3089.0 |                                                          1      2      3  |