 Normative referencesItalian standard: CEI 20-20/5
 International standard: CENELEC HD 21.5 Sez. 3
 
 Technical Data
 Voltage Rating: 300/300 V
 Temperature Rating: 60 °C
 Max Tensile Strength: 50 N/mm2
 Minimum Bend Radius: 4 times outside cable diameter
 
 Constructive data
 Flexible conductors of not tinned annealed copper
 Insulation: quality TI2 of polyvinyl chloride
 Jacket: quality TM2 of polyvinyl chloride
 
 Colouring
 2 cores: brown, blue
 3 cores: black, brown, blue
 4 cores: black, black, brown, blue
 
                                      
                                        
                                          | Type  | No. of cores per cross- sectional area | Diameter of wires   Max. | Insulation  thicknessMin.
 | Jacket thickness Min. | Outside cable diameter      Min.     Max.
 | Insulation resistance at 70°C Min. |  
                                          | A03VV-F | N x mm2 | mm | mm | mm |  mm | mm | MohmKm |  
                                          | 2 G 0,50 | 0,21 | 0,5 | 0,6 | 4,6 | 5,9 | 0,012 |  
                                          | 2 G 0,75 | 0,21 | 0,5 | 0,6 | 4,9 | 6,3 | 0,010 |  
                                          | 3 G 0,50 | 0,21 | 0,5 | 0,6 | 4,9 | 6,3 | 0,012 |  
                                          | 3 G 0,75 | 0,21 | 0,5 | 0,6 | 5,2 | 6,7 | 0,010 |  
                                          | 4 G 0,50 | 0,21 | 0,5 | 0,6 | 5,4 | 6,9 | 0,012 |  
                                          | 4 G 0,75 | 0,21 | 0,5 | 0,6 | 5,7 | 7,3 | 0,010 |  
                                      
                                      
                                     |